Description of Triplett Railroad Test Set

Scroll to Pricing

Now heres something new, an analog meter designed for measuring the signal parameters of railroad coding equipment. The Triplett Railroad test set is available in four models (2000-2003), the lower versions are all upgradeable. Each later model has all of the features of its predecessor, plus a few additional features not commonly found on standard VOMs. These railroad voltage meters are easier to use for normal operation functions and give the user the control.

Made with a modular design, the Railroad test Digital meter is easily customizable for individual job needs. Regardless of polarity, the basic tester code parameters are able to detect foreign voltage in any AC or DC range; measure voltage, current, resistance, and relay contact on time. Each Triplett Railroad model following 2000 has varying ranges of cab filters, from 60 to 250Hz.

Contents of each kit includes: test set, test leads, spare fuses, two 9V alkaline batteries, one D-cell alkaline battery, carrying case and instruction manual.


Review this item After receiving your order add a new product review here and receive 10% Off on your next order!!

Features and Benefits

  • Each model is upgradeable
  • Auto Polarity in DC functions
  • Selectable DC Amps polarity
  • Direct measurement of code parameters
  • Relay contact on time (dry contact), requires no adjustment
  • Ohm meter voltage mode detects either polarity voltage including AC
  • Field replaceable protective window
  • One Year Standard Warranty

More Info

DC VoltageRanges: 0.6, 3, 15, 60, and 300 VDC
Accuracy: 1.5% of full scale
Sensitivity: 1000 Ohms per volt
DC MilliampsRanges: 15, 60, and 300 mA DC
Accuracy: 1.5% of full scale
Burden Volts: 60 mV nominal
DC AmpsRanges: 1, 5, 6, and 30 Amps DC
Accuracy: 1.5% of full scale
Burden Volts: 60 mV nominal
AC VoltageRanges: 1.5, 3, 15, 150, 300, and 600 VAC
Accuracy: 3.0% of full scale
Sensitivity: 288 Ohms per volt
Calibration: Average responding, RMS calibrated
Frequency Response: 25Hz to 400Hz
AC AmpsRanges: 1.5, 6, and 30 Amps AC
Accuracy: 3.0% of full scale
Burden Volts: 60 mV nominal
Calibration: Average responding, RMS calibrated
Frequency Response: 25Hz to 400Hz
Cab Filter Response (All AC Ranges)60Hz Filter: 57 to 64Hz (2013)
100Hz Filter: 92 to 100HZ (2011, 2012, 2013)
200Hz Filter: 245 to 255Hz (2012)
250Hz Filter: 245 to 255Hz (2011)
All filters introduce an additional 1.5% level error
Code Functions(All AC and DC Ranges)On Time
Range: 3% to 100%
Accuracy: 3.0% of full scale
Range: 30 to 500 CPM
Accuracy: 3.0% of scale length
Peak Hold: Captures and holds highest level peak
peak Follow: Displays all peaks > 25% of previous
Ohm MeterVoltage Sense Mode
Range: 15 VAC or DC
Accuracy: 20% Typical
Sensitivity: 1000 Ohms per volt
Resistance Measurement Mode
Ranges: R x 1 and R x 100
Center Scale: 5 and 500 Ohms
Accuracy: 2% of scale length 0.5 Ohms
Open Circuit Voltage: 1.0 to 1.8 VDC
Dry ContactAllowable Contact Resistance: 0 to 100 Ohms
Test Voltage: 7.5 to 15 VDC
Test Current: 830 A max
On Time
Range: 0 to 100%
Accuracy: 2% of full scale
Rate
Range: 30 to 500 cycles per min
Accuracy: 3% of scale length
Peak Hold: Pointer will deflect to full scale and remain there with a 2.0 mS or longer contact closure.
Power RequirementsBatteries: Two 9V alkaline, One 1.5V alkaline
Battery life: 320hrs typical, 2000hrs in Sleep Mode
Meter MovementElectrical: 100 A 1% at full scale
Construction: Taut band, shock mounted, 100 deflection, critically damped, Mirrored scale, Bar-ring magnet
Physical SpecsSize: 5.0" W x 6.5" H x 3.2" D
Weight: Approx 4.75lbs with case and leads
Operating Temp Range: -40C to +85C