Model No. |
UPS-1000R |
UPS-2200R |
Standard runtime at Half Load |
26 minutes |
13 minutes |
Standard runtime at Full Load |
13 minutes |
6 minutes |
Maximum runtime at Half Load |
1196 minutes |
575 minutes |
Maximum runtime at Full Load |
575 minutes |
200 minutes |
|
Input |
Nominal Input Voltage |
120V |
120V |
Input Voltage Range |
80Vac-145Vac |
80Vac-145Vac |
Input Frequency |
60 Hz± Hz (auto sensing) |
60 Hz± 3 Hz (auto sensing) |
Input Protection Type |
Resettable thermal fuse |
Resettable thermal fuse |
Cord Length/Plug Type |
9 ft./NEMA 5-15P |
9 ft. / NEMA 5-15P |
|
Output |
Green Mode Consumption |
Less than 9W at full battery capacity |
Less than 9W at full batter capacity |
Nomimal Output Voltage |
120V |
120V |
Capacity (VA) |
1000VA |
2150VA |
Capacity (Watts) |
750W |
1650W |
Waveform |
Pure Sine Wave |
Pure Sine Wave |
Online Output Frequency |
57-63 Hz for 60 Hz nominal |
57-63 Hz for 60 Hz nominal |
On Battery Output Frequency |
60 Hz± 0.1 Hz |
60 Hz± 0.1Hz |
Transfer Time (Typical) |
4 ms typical line to battery / battery to line |
4 ms typical line to batter / battery to line |
100%≤Load<110% warning, 120 sec shutdown |
100%≤Load<100% warning, 120 sec shutdown |
Overload Protection (on line mode) |
110%≤Load<125% warning, 40 sec shutdown |
110%≤Load<125% warning, 40 sec shutdown |
125%≤Load warning, 10 sec shutdown |
125%≤Load warning, 10 sec shutdown |
100%≤Load<110% warning, 30 sec shutdown |
100%≤Load<110% warning, 30 sec shutdown |
Overload Protection (on battery mode) |
110%≤Load<125% warning, 10 sec shutdown |
110%≤Load<125% warning, 10 sec shutdown |
125%≤Load warning, 3 sec shutdown |
125%≤Load warning, 3 sec shutdown |
|
Surge Protection and Filtering |
Lightning / Surge Protection |
L-N=>381 J (127J x 3) Clamp voltage 270V (Max energy 10/1000 us) |
L-N=>381 J (127j x 3) Clamp voltage 270V (Max Energy 10/1000 us) |
RJ11 / RJ45 Protection |
Sidactorx1 Clamp Voltage 275V Fuse (0.75A / 250V) x 2 |
Sidactrox1 Clamp Voltage 275V Fuse (0.75A / 250V) x 2 |
|
Physical |
Output Receptacles |
(8) NEMA 5-15R |
(8) NEMA 5-20R |
Dimensions (in.) |
19" [423]W x 3.5" [89]H x 19.29" [490]D |
19" [423]W x 3.5" [89]H x 19.29" [490]D |
Weight |
68 lbs. |
77 lbs. |
|
Battery |
Rating |
12V / 9.0 AH x 4 |
12V / 9.0 AH x 4 |
Auto Charger |
1A |
1A |
Hot Swappable External Battery |
Yes |
Yes |
Runtime at Half Load |
26 minutes |
14 minutes |
Runtime at Full Load |
13 minutes |
6.4 minutes |
|
Warning Diagnostics |
Control Panel |
LCD Display Indicators, Power On |
LCD Display Indicators, Power On |
Audible |
On Battery, Low Battery |
On Battery, Low Battery |
|
Environmental |
Operating Temperature |
32ºF to 104ºF (0ºC to 40ºC) |
32ºF to 104ºF (0ºC to 40ºC) |
Operating Relative Humidity |
0 to 95% Non-Condensing |
0 to 95% Non-Condensing |
|
Communication |
Software |
Middle Atlantic Power Manager |
Middle Atlantic Power Manager |
|
Management |
Self-Test |
Manual Self-Test via front panel |
Manual Self-Test via front panel |
Auto-Charger/Auto-Restart |
Yes |
Yes |
|
COM Interface |
Primary |
-RS232 Communication + Control -Analog Status Notification + Control |
-RS232 Communication + Control -Analog Status Notification + Control |
Secondary |
-Analog status notification only |
-Analog status notification only |
Built-in USB Interface |
Yes |
Yes |